Interior fan driving me crazy

Talk about the 406's electrical system, what wires do what, how to add extra functionality, etc.

Moderator: Moderators

Post Reply
Puggy2
2.0 16v
Posts: 139
Joined: Sun Nov 03, 2013 6:16 pm
Location: Byfleet Surrey

Interior fan driving me crazy

Post by Puggy2 »

Hi all this is getting stupid. Have owned my 2.0 HDi for 3 years ever since I have had it the internal fan has had a mind of its own comes on when it feels like it sometimes works for a month sometimes a few minutes. Anyway my wife also has a 406 as well all working so I have swopped the fan control unit over and mine works her car so no problem there, a few months ago I joined the 2 wires from the ignition switch to see if it was the ignition switch. I then discovered by accident that the connector in passenger footwell with the red to green/yell & black to grey was causing the problem I could make the fan go off by wiggling the wires so I cut the connector out and crimped the 2 pairs of wires. This is when it starts getting crazy, now the blower runs at full speed even in aux position on ignition with no control from dashboard so I removed the joint at the ignition switch and the blower now does not work at all, is there something in that connector ? Sorry for the long post Iain.
scotty73
3.0 24v
Posts: 2580
Joined: Mon Jan 16, 2012 12:38 pm
Location: Rhymney, south Wales.

Re: Interior fan driving me crazy

Post by scotty73 »

there's another one? :shock:
2000 W 2.0hdi 110 7 seat estate Blue.
Image

Image
And this glue is for my submarine not for putting up you're f*c*ing noses, and dont think i dont notice cos i do... Buy your own f*c*ing glue!!! Fatty Lewis Twin town 1997.
User avatar
puggy
Resident Pervert
Posts: 3251
Joined: Tue May 01, 2007 7:47 am
Location: staffordshire

Re: Interior fan driving me crazy

Post by puggy »

Mmmmmm seems so scotty :shock:
.. ooh are those drugs for me Matron
Puggy2
2.0 16v
Posts: 139
Joined: Sun Nov 03, 2013 6:16 pm
Location: Byfleet Surrey

Re: Interior fan driving me crazy

Post by Puggy2 »

So no one knows then. :(
FarmerPug
2.0 HDI 110
Posts: 9656
Joined: Tue Jun 01, 2010 5:42 pm
Location: The Countryside, Northern Ireland
Contact:

Re: Interior fan driving me crazy

Post by FarmerPug »

The motor goes to a resistor, and then to the climate control. When you say fan control unit do you mean the resistor or climate control.

This is the resistor part:
http://www.ebay.co.uk/itm/NEW-HEATER-BL ... 4d099560e8

Its located in the footwell area to the right of the blower motor.
Puggy2
2.0 16v
Posts: 139
Joined: Sun Nov 03, 2013 6:16 pm
Location: Byfleet Surrey

Re: Interior fan driving me crazy

Post by Puggy2 »

I mean the resistor which really is a bit more than a resistor, it is a transistorized speed controller.The bit that is getting me is just by making a permenant joint on the 2 cables has caused so much trouble.
FarmerPug
2.0 HDI 110
Posts: 9656
Joined: Tue Jun 01, 2010 5:42 pm
Location: The Countryside, Northern Ireland
Contact:

Re: Interior fan driving me crazy

Post by FarmerPug »

Any alterations to the electrical system on a pug can do this sort of thing, especially if its multiplexed is your car newer than 2001?
Puggy2
2.0 16v
Posts: 139
Joined: Sun Nov 03, 2013 6:16 pm
Location: Byfleet Surrey

Re: Interior fan driving me crazy

Post by Puggy2 »

No 2000 pre comm2000 stalks etc
FarmerPug
2.0 HDI 110
Posts: 9656
Joined: Tue Jun 01, 2010 5:42 pm
Location: The Countryside, Northern Ireland
Contact:

Re: Interior fan driving me crazy

Post by FarmerPug »

When you crimped the wires is there any change the wrong wires got connected together? Or was it done just to bypass the faulty plug/connector.
Puggy2
2.0 16v
Posts: 139
Joined: Sun Nov 03, 2013 6:16 pm
Location: Byfleet Surrey

Re: Interior fan driving me crazy

Post by Puggy2 »

Just to get rid of faulty plug, I am fully qualified mechanic/aircraft electrician
Puggy2
2.0 16v
Posts: 139
Joined: Sun Nov 03, 2013 6:16 pm
Location: Byfleet Surrey

Re: Interior fan driving me crazy

Post by Puggy2 »

Just bringing this back as I still can't work this out.


Hi all this is getting stupid. Have owned my 2.0 HDi for 3 years ever since I have had it the internal fan has had a mind of its own comes on when it feels like it sometimes works for a month sometimes a few minutes. Anyway my wife also has a 406 as well all working so I have swopped the fan control unit over and mine works her car so no problem there, a few months ago I joined the 2 wires from the ignition switch to see if it was the ignition switch. I then discovered by accident that the connector in passenger footwell with the red to green/yell & black to grey was causing the problem I could make the fan go off by wiggling the wires so I cut the connector out and crimped the 2 pairs of wires. This is when it starts getting crazy, now the blower runs at full speed even in aux position on ignition with no control from dashboard so I removed the joint at the ignition switch and the blower now does not work at all, is there something in that connector ? Sorry for the long post Iain.
User avatar
jonsowman
3.0 24v
Posts: 1707
Joined: Wed Sep 21, 2011 4:19 pm
Location: Surrey, UK (J9 M25)

Re: Interior fan driving me crazy

Post by jonsowman »

It might be the speed controller as previously mentioned, the fault just happened to occur at the same time.

The "blower running full speed" thing is almost always this control unit.

The transistor fails closed, but it's not a random failure. It will only occur when the controller is set to full speed - it then sticks there. So during your experimentation to see whether your fix worked, if you tested at full speed, that could have triggered the transistor failure in the unit.

Swap the control unit from your wife's car - it only takes 10 mins and it'll tell you whether that's the issue.
Image
2002 V6 SE Coupé (210bhp) - (Aegean Blue)
2002 D9 2.2 HDi Exec Estate - Samarkand Blue
PM me for PP2000 diagnostics around Surrey