Blower Motor Control Unit

Talk about the 406's electrical system, what wires do what, how to add extra functionality, etc.

Moderator: Moderators

Post Reply
Malc
2.0 16v
Posts: 125
Joined: Thu Apr 08, 2010 1:50 am

Blower Motor Control Unit

Post by Malc »

Looks like my blower motor control unit (LHD 406 Hdi...Unit with two green sockets in the passenger foot-well) has failed again and I've ordered a replacement via ebay.
Wonder if anyone has perchance a circuit diagram of this unit as I'd like to have a go and see if I can repair or at least find out what the hell goes wrong so frequently with this nuisance.
boudy
Newbie
Posts: 5
Joined: Mon May 25, 2015 10:36 pm

Re: Blower Motor Control Unit

Post by boudy »

I have replaced it four months ago and it work well now :D ...
Don't try to repair it,,, it could work for awhile and cause malfuction ---> engine overheating
Puggy2
2.0 16v
Posts: 139
Joined: Sun Nov 03, 2013 6:16 pm
Location: Byfleet Surrey

Re: Blower Motor Control Unit

Post by Puggy2 »

boudy wrote:I have replaced it four months ago and it work well now :D ...
Don't try to repair it,,, it could work for awhile and cause malfuction ---> engine overheating
Wrong blower he means cabin blower
PeterN
3.0 24v
Posts: 1673
Joined: Sun Mar 04, 2012 6:04 pm
Location: Charmouth, Dorset

Re: Blower Motor Control Unit

Post by PeterN »

I don't know if its the same as the one in the XM/Xantia but if it is you can repair them if you are handy with a soldering iron. The regulator transtors fail, they are obtainable and not to difficult to fit.

Peter